FUNCTION BLOCK
|
|
|
|
FUNCTION
|
|
|
|
|
|
|
Counts pulses and displays a number from 0-99.
- Counts low-to-high pulses on the Clock (CK) input, onto 7-segment displays
- Has 3 control inputs
- Inputs and outputs aligned so displays can be cascaded
|
|
|
|
|
|
OUTPUTS:
|
INPUTS: |
|
|
|
|
|
CK
CO
R
LT
|
=Clock (same as input)
=Carry Out, low when=99
=Reset (same as input)
=Latch (same as input) |
CK
-EN
R
LT
|
=Clock, input pulses
=Enable, counts when low
=Reset, display=00 when high
=Latch, display freezes when high but keeps counting. |
|
|
|
|
|
Supply Voltage (+V): 4.5 to 12 volts |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
www.edutek.ltd.uk - Working Electronics For Students & Teachers
|
|
|
|
|
|